EU 1000i and EU 2000i
fire patch.gif
SECTION: Tools and Equipment
ISSUED: 02-2011REVISED: ##-####
Objectives
To provide an understanding of thefollowing
Specifications
Use
Maintenance
Safety
EU-1000i
eu1000i
Specifications
Engine
4 Stroke
1 Cylinder
5,500 rpm
Forced Air Cooling
2.1 Liter Fuel Capacity
0.25 Liter Oil
SAE 10W-30
Spark Plug
CR5HSB (NGK)
U16FSR-UB(NIPPONDENSO)
Generator (AC Output)
Rated Voltage of 120 Volts
Rated Frequency of 60 Hz
Rated Amperage of 7.5Amps
Rated Output of 900 VoltAmps
Maximum Output of 1000Volt Amps
Generator (DC Output)
Only charges 12 Volt AutoBatteries
Maximum output of 8 Amps
EU-2000i
eu1000i
Specifications
Engine
4 Stroke
1 Cylinder
4,300 – 5,000 rpm
Forced Air Cooling
3.6 Liter Fuel Capacity
0.4 Liter Oil
SAE 10W-30)
Spark Plug
CR5HSB (NGK)
AC Output
Rated Voltage of 120 Volts
Rated Frequency of 60 Hz
Rated Amperage of 13.3Amps
Rated Output of 1,600 VoltAmps
Maximum Output of 2,000Volt Amps
DC Output
Only charges 12 Volt AutoBatteries
Maximum output of 8 Amps
EU1000 parts
Use
Provides lighting during incidents
To provide a power source for equipment
Starting Procedure
Turn on valve cap vent
Switch fuel to on position
Choke should be in the closed position
Pull starter grip briskly
Do NOT allow cord to snap back
Once engine starts to run, open choke
Maintenance
Clean, refuel, and check oil and air filter after each use
Mondays
Check fluids for proper levels
Check air filter
Check overall condition
Run engine with the light on to ensure proper operation
Storage
Ensure fuel tank is full
Ensure choke is closed
Ensure fuel switch is turned off
Ensure fuel vent cap is turned off
Ensure flood light turned off
Maintenance
Annual service
Engine Oil
Air Filter
Spark Plug
Fuel Filter
Safety
If the load placed on unit exceeds its maximumoutput the unit will automatically shut down toavoid damage
In the event this happens let the unit sit for a fewminutes, re-evaluate the load and restart
While in operation keep light on to maintainvisibility when necessary
Try to avoid use in enclosed areas
Monitor air quality for CO build up if used in enclosedarea
Avoid running electrical cords down walk ways